Answer:
The current drawn from the outlet is 0.2 A
The number of turns on the input side is 350 turns
Explanation:
Given;
number of turns of the secondary coil, Ns = 35 turns
the output current, [tex]I_s[/tex] = 2 A
power supplied, [tex]P_s[/tex] = 24 W
the standard wall outlet in most homes = 120 V = input voltage
For an ideal transformer; output power = input power
the current drawn from the outlet is calculated;
[tex]I_pV_p = P_s\\\\I_p = \frac{P_s}{V_p} = \frac{24}{120} = 0.2 \ A[/tex]
The number of turns on the input side is calculated as;
[tex]\frac{N_p}{N_s} = \frac{I_s}{I_p} \\\\N_p = \frac{N_sI_s}{I_p} \\\\N_p = \frac{35 \times 2}{0.2} \\\\N_p = 350 \ turns[/tex]